Product Water Produced per hour of operation:
+-15% 850 psi / 56 Bar, 77oF / 25oC & 35,000 ppm TDS typical sea water
| Model |
Production Per Hour
|
Production Per 24 Hours
|
|
gallons/liters
|
gallons/liters
|
| SFM 450-1 |
19 / 71
|
450 / 1,703
|
| SFM 700-1 |
29 / 110
|
700 / 2,650
|
| SFM 900-1 |
38 / 142
|
900 / 3,407
|
| SFM 900-2 |
38 / 142
|
900 / 3,407
|
| SFM 1400-2 |
58 / 221
|
1,400 / 5,300
|
| SFM 1800-2 |
75 / 284
|
1,800 / 6,814
|
Salt Rejection (Chloride Ion):
Minimum 99.2%, Average 99.4%
Product Water Temperature:
Ambient to feed water temperature.
Salinity Monitoring:
The salinity monitoring components of the system give a continuous readout in micromhos per cubic centimeter, are temperature compensated, and of a fail safe design.
Salinity Range:
Designed for seawater use up to 50,000 ppm TDS (Nacl)
(typical seawater salinity is 35,000 ppm.)
Temperature Range:
Min. 33oF / .5oC Max. 122oF / 50oC
System Feed Water:
Flow: 50Hz, 3.5 gpm / 13.2 lpm; 60Hz, 3 - 4.2 gpm / 11.4 - 15.9 lpm
Reverse Osmosis Membrane:
High Rejection/High Yield aromatic tri-polyamind, thin film composite, spiral wound, single pass reverse osmosis membrane element.
Chlorine Tolerance:
0.1 ppm
pH Range:
3-11 (typical seawater pH is 8)
System Pressure:
| Feed Water: |
Minimum: |
6 psi / .41 bar / .42 Kg/cm2 |
|
Maximum: |
35 psi / 2.41 bar / 2.46 Kg/cm2 |
|
|
|
System Operation: Typical seawater has a salinity of 35,000 ppm TDS and an average temperature of 77oF / 25oC.
Nominal: 850 psi / 56.5 bar / 57.66 Kg/cm2. (Brackish varies w/ppm)
Weight:
|
Model Number
|
Weight
|
SFM 450-1
SFM 700-1
SFM 900-1
SFM 900-2
SFM 1400-2
SFM 1800-2
|
118 lbs / 54 Kg
125 lbs / 57 Kg
136 lbs / 62 Kg
136 lbs / 62 Kg
147 lbs / 67 Kg
150 lbs / 68 Kg
|
External Installation Water Connections:
Pipe sizes to be supplied by the installer for connection of the Horizon Reverse Osmosis supplied components.
| Feed Inlet: |
3/4" MNPT (Male National Pipe Thread, Amer. Std) |
| Brine Discharge: |
1/2" FNPT (Male National Pipe Thread, Amer. Std) |
| Product: |
3/8" FNPT (Female National Pipe Thread, Amer. Std) |
Electrical Motor Specifications:
(HP = Horse Power; FLA = Full Load Amperes, LRA = Locked Rotor Amperes @ Start Up)
High Pressure Pump Electric Motor:
450-1 & 900-2 Systems:
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50 |
110 |
2.2 |
21 |
121 |
| Single |
50 |
220 |
2.2 |
10.5 |
60.5 |
| Three |
50 |
220 |
3.0 |
9.2 |
78 |
| Three |
50 |
380 |
3.0 |
4.6 |
39 |
|
|
|
|
|
|
| Single |
60 |
115 |
2.2 |
18 |
94 |
| Single |
60 |
230 |
2.2 |
9 |
47 |
| Three |
60 |
230 |
3.0 |
8.2 |
70 |
| Three |
60 |
460 |
3.0 |
4.1 |
35 |
High Pressure Pump Electric Motor:
700-1 & 1400-2 and 900-1 & 1800-2 Systems:
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50 |
110 |
2.2 |
21 |
121 |
| Single |
50 |
220 |
2.2 |
10.5 |
60.5 |
| Three |
50 |
220 |
3.0 |
9.2 |
78 |
| Three |
50 |
380 |
3.0 |
4.6 |
39 |
|
|
|
|
|
|
| Single |
60 |
115 |
2.6 |
21.2 |
109 |
| Single |
60 |
230 |
2.6 |
10.6 |
54.5 |
| Three |
60 |
230 |
3.0 |
8.2 |
70 |
| Three |
60 |
460 |
3.0 |
4.1 |
35 |
Booster Pump Motors:
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50/60 |
115 |
.5 |
7.4 |
34 |
| Single |
50/60 |
220/230 |
.5 |
3.7 |
17 |
| Three |
50/60 |
220/230 |
.5 |
2 |
12 |
| Three |
50/60 |
380/460 |
.5 |
1 |
6 |
Recommended Circuit Breaker:
|
Operating Voltage Hz & Phase
|
|
Rec. Circuit Breaker Size
|
115 VAC, Single Phase
230 VAC, Single Phase
208/230 VAC, Three Phase
380 VAC, Three Phase
460 VAC, Three Phase
|
|
35 Amps
15 Amps
10 Amps
7.5 Amps
7.5 Amps
|
|
|