System Specifications
 
Product Water Produced per hour of operation:
+-15% 850 psi / 56 Bar, 77oF / 25oC & 35,000 ppm TDS typical sea water
 
Model
Production Per Hour
Production Per 24 Hours
gallons/liters
gallons/liters
SFM 450-1
19 / 71
450 / 1,703
SFM 700-1
29 / 110
700 / 2,650
SFM 900-1
38 / 142
900 / 3,407
SFM 900-2
38 / 142
900 / 3,407
SFM 1400-2
58 / 221
1,400 / 5,300
SFM 1800-2
75 / 284
1,800 / 6,814
 

Salt Rejection (Chloride Ion):
Minimum 99.2%, Average 99.4%

Product Water Temperature:

Ambient to feed water temperature.

Salinity Monitoring:

The salinity monitoring components of the system give a continuous readout in micromhos per cubic centimeter, are temperature compensated, and of a fail safe design.

Salinity Range:
Designed for seawater use up to 50,000 ppm TDS (Nacl)
(typical seawater salinity is 35,000 ppm.)


Temperature Range:
Min. 33oF / .5oC Max. 122oF / 50oC

System Feed Water:
Flow: 50Hz, 3.5 gpm / 13.2 lpm; 60Hz, 3 - 4.2 gpm / 11.4 - 15.9 lpm

Reverse Osmosis Membrane:
High Rejection/High Yield aromatic tri-polyamind, thin film composite, spiral wound, single pass reverse osmosis membrane element.

Chlorine Tolerance:
0.1 ppm

pH Range:

3-11 (typical seawater pH is 8)

System Pressure:

Feed Water: Minimum: 6 psi /   .41 bar /   .42 Kg/cm2
Maximum: 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation: Typical seawater has a salinity of 35,000 ppm TDS and an average temperature of 77oF / 25oC.
Nominal: 850 psi / 56.5 bar / 57.66 Kg/cm2. (Brackish varies w/ppm)


Weight:
Model Number
Weight

SFM 450-1
SFM 700-1
SFM 900-1
SFM 900-2
SFM 1400-2
SFM 1800-2

118 lbs / 54 Kg
125 lbs / 57 Kg
136 lbs / 62 Kg
136 lbs / 62 Kg
147 lbs / 67 Kg
150 lbs / 68 Kg


External Installation Water Connections:
Pipe sizes to be supplied by the installer for connection of the Horizon Reverse Osmosis supplied components.

Feed Inlet: 3/4" MNPT (Male National Pipe Thread, Amer. Std)
Brine Discharge: 1/2" FNPT (Male National Pipe Thread, Amer. Std)
Product: 3/8" FNPT (Female National Pipe Thread, Amer. Std)


Electrical Motor Specifications:
(HP = Horse Power; FLA = Full Load Amperes, LRA = Locked Rotor Amperes @ Start Up)

High Pressure Pump Electric Motor:

450-1 & 900-2 Systems
:
Phase Hz VAC HP FLA LRA
Single 50 110 2.2 21 121
Single 50 220 2.2 10.5 60.5
Three 50 220 3.0 9.2 78
Three 50 380 3.0 4.6 39
Single 60 115 2.2 18 94
Single 60 230 2.2 9 47
Three 60 230 3.0 8.2 70
Three 60 460 3.0 4.1 35

High Pressure Pump Electric Motor:

700-1 & 1400-2 and 900-1 & 1800-2 Systems
:
Phase Hz VAC HP FLA LRA
Single 50 110 2.2 21 121
Single 50 220 2.2 10.5 60.5
Three 50 220 3.0 9.2 78
Three 50 380 3.0 4.6 39
Single 60 115 2.6 21.2 109
Single 60 230 2.6 10.6 54.5
Three 60 230 3.0 8.2 70
Three 60 460 3.0 4.1 35

Booster Pump Motors:
Phase Hz VAC HP FLA LRA
Single 50/60 115 .5 7.4 34
Single 50/60 220/230 .5 3.7 17
Three 50/60 220/230 .5 2 12
Three 50/60 380/460 .5 1 6

Recommended Circuit Breaker:
Operating Voltage Hz & Phase
Rec. Circuit Breaker Size

115 VAC, Single Phase
230 VAC, Single Phase
208/230 VAC, Three Phase
380 VAC, Three Phase
460 VAC, Three Phase

35 Amps
15 Amps
10 Amps
7.5 Amps
7.5 Amps

Job Opportunities Business Opportunities How to Order Boat Shows Technical Brochures Contact Us Job Opportunities Company Profile Dealer Network Products and Specs Home